Ensure the O-ring is fitted into the groove of the flange. Turn the pressure regulator adjustment screw clockwise. The three-position manual gas control knob has ON, OFF, and PILOT positions. 0000002388 00000 n These Videos are all part of our Training Series on HVACR Service, Installation, Preventative Maintenance, General Knowledge, and Tips. ' b1?T3/0.!0s.2c7oDp!c{|87*G2s>y~O9SNF. Then the regulator valve is forced fully open by the timing diaphragm, which is operated by bleed gas. (supposedly so they could fix them :yes: ). The generator, heated by the pilot burner flame, pro- . Your email address will not be published. In replacement applications, locate the gas control in the same location as the old gas control. 0000126162 00000 n See Fig. If necessary, adjust the pressure regulator to match the appliance rating. 2 and 3. Force or attempted repair may result in fire or explosion. If the gas control knob or reset button will not operate by hand, or if the reset button stays depressed after it is released, the gas control should be replaced by a qualified service technician. If tubing is used, ensure the ends are square, deburred and clean. 0000028628 00000 n startxref The first automatic valve opens, and the second automatic valve operator valve disc is lifted off its seal. The screw to adjust the pilot gas is a needle valve. On LP installations, use compound resistant to LP gas. 0000031335 00000 n 0000011088 00000 n Set the thermostat or the device's controller slightly above the current room temperature. On LP gas installation, use compound resistant to LP gas. Is a PhD visitor considered as a visiting scholar? Circuit Millivolt Check Symptom - Intermittent shutdown or main burner will not light with on/off switch. . IF THE PILOT BURNER FLAME GOES OUT WHEN THE GAS CONTROL KNOB IS RELEASED, IF THE MAIN BURNER WILL NOT COME ON WITH A CALL FOR HEAT. There is a heat anticipator coil in there which limits current to the valve, and shorting that out can damage the valve. 0000023014 00000 n %PDF-1.3 % I have a Superior Gas Fireplace model DR-500CMP that currently has a Honeywell Millivolt Gas Valve that I need to replace but the part number does not cross to a valid number. Taps are 1/8 inch NPT with a plug containing recess for 3/16 inch Allen wrench.PRESSURE RATING: A.G.A. 0000013040 00000 n The maintenance program should include regular checkout of the gas control, see the Startup and Checkout section, and the control system as described in the appliance manufacturer literature. If the pilot flame is engulfing the thermopile and you are not getting enough voltage to open the main gas valve then the thermopile may need to be replaced.Supervision is needed by a licensed HVAC Tech while doing this as Experience and Apprenticeship garners Wisdom and Safety.We've Partnered with TruTechTools.com! If the pilot flame goes out, turn the gas control knob clockwise, If the pilot flame remains lit, turn the gas control knob counterclockwise. May be installed at any angle between 0 and 90 degrees from the upright position, including vertically. 0000023456 00000 n Why are Suriname, Belize, and Guinea-Bissau classified as "Small Island Developing States"? Usually this problem can be resolved by using an adapter. Extinguish pilot flame. See Fig. This is a legacy product document supported by Resideo.This product is no longer manufactured. 0000006973 00000 n Adjust the thermostat several degrees above room temperature. Required fields are marked *. I go over what to do if you are not receiving the correct voltages. Robertshaw low profile millivolt gas valve- http://amzn.to/2iLXzEhWhite Rodgers 750mv thermopile- http://amzn.to/2zhKVnFRobertshaw pilot and thermopile combo-http://amzn.to/2zZAH8wHoneywell 750mv thermopile- http://amzn.to/2yfR9UKThermopile and Millivolt Gas Valve Troubleshooting Video-https://youtu.be/riaN_j5tmX4Thermopile Testing- https://youtu.be/63zFDe6P1bkWater Heater Thermopile and Millivolt Gas Valve Troubleshooting- https://youtu.be/RASBzK_XF2kHere are some of the Tools I use:Yellow Jacket Refrigerant Gauge Set http://amzn.to/2aenwTqRefrigerant hoses with valves http://amzn.to/2aBumVIYellow Jacket Gauge set \u0026 hoses https://amzn.to/2vLVkV9Yellow Jacket 4 Port Manifold w Hoses https://amzn.to/2BkuGIqFieldpieceSMAN360 Digital Manifold Set https://amzn.to/2BdoaD4FieldpieceSMAN460 Digital Manifold Set https://amzn.to/2nB4Fe6Compact Ball Valve for Refrigerant Hose https://amzn.to/2KUisW8QuickDisconnect 90 for refrigerant hose https://amzn.to/2MMtVcgUEI DL479 Multimeter with temp sensor http://amzn.to/2jtsUbJJB 6 CFM Vacuum Pump http://amzn.to/2nqbvo8Appion Blue 3/8\" to 1/4\" Vacuum Hose http://amzn.to/2uYlVycAppion Red 3/8\" to 1/4\" Vacuum Hose http://amzn.to/2uYg6RoAppion Valve Core Removal Tool http://amzn.to/2uYr8WLYellow Jacket 1/4\" by 1/4\" hose http://amzn.to/2umtcodCPS Vacuum Micron Gauge http://amzn.to/2v1nM3OSupco Vacuum Micron Gauge http://amzn.to/2v1JRiARectorSeal Bubble Gas Leak Detector http://amzn.to/2ckWACnUEI DL389 Multimeter http://amzn.to/2xAdaJfFieldpiece ST4 Dual Temp Meter http://amzn.to/2wc1ME3Air Acetylene Torch setup http://amzn.to/2aQalsb 15% Silver Brazing Rods http://amzn.to/2gVLyLcNitrogen Regulator http://amzn.to/2bXdR5fNitrogen Flow Meter http://amzn.to/2brvoBgDigital Refrigerant Scale http://amzn.to/2b9oXYl Accutrak VPE Ultrasonic Leak Detector https://amzn.to/2nFYKVeImperial Kwik Charge 535-C http://amzn.to/2uipEI6 FieldpieceSDMN6 Dual Manometer Pump http://amzn.to/2jyK5KaSupco Magnet Jumpers http://amzn.to/2gS4h6z2 pairs of alligator clips- http://amzn.to/2CtIL5zJB Vacuum Pump Oil http://amzn.to/2mGrlXyGeneral Tools digital Psychrometer http://amzn.to/2cSHsi1Fieldpiece SDP2 Digital Psychrometer http://amzn.to/2nniMVRRatcheting Service Wrench http://amzn.to/2dGV4NhAppion G5 Twin Recovery Pump http://amzn.to/2dGSEyr Irwin Wire Stripper/Cutter/Crimper http://amzn.to/2dGTj2VShop through Amazon! 0000017038 00000 n wc [0 kPa] to rated output pressure within 3-6 seconds (for an 80,000 Btuh furnace at 7 in. 2 or 3. 0000006449 00000 n Home Improvement Stack Exchange is a question and answer site for contractors and serious DIYers. 0000055329 00000 n Connect the other end of the tubing to the pilot burner according to pilot burner manufacturer instructions. Come join the discussion about tools, projects, builds, styles, scales, reviews, accessories, classifieds, and more! Do not remove seals until ready to connect piping.Follow the appliance manufacturer instructions if available; otherwise, use the instructions provided below. There should not be a flame-up there if the valve is working correctly. The Robertshaw - Uni-Line 700-500 and 710-500 Series millivolt gas valves are thermostatically actuated com- bination gas valves. Standard-, slow- and step-opening models available. Repeat after allowing the main burner to cool. If either of the switches is bad, no go. See Fig. Mount the gas control so gas flow is in the direction of the arrow on the bottom of the gas control. Minimum regulated capacity is 20 feet 3 /hour [0.6 meters 3 /hour]. TABLE 8PRESSURE REGULATOR SPECIFICATION PRESSURES IN kPa. A separate reset button must be held down to permit gas flow while lighting the pilot; can be pushed down only in the PILOT position. I suspect they are the "white" terminal and TH1. If it goes out, repeat steps 36. 0000126186 00000 n %PDF-1.5 % If the inlet pressure is in the normal range (refer to Table 7 or 8), replace the gas control. 0000002263 00000 n Water heater not working? For the battery test above only connect the battery for a second or two just to see if the gas valve works. I show you how to Light the Pilot and Power the Main Burner! 0000008848 00000 n I would verify the valve type - It would either be the SIT 820 or the Honeywell VS8420. Assure the gas control knob is in the ON position. 0000042992 00000 n Terminal block color-coded beige.THERMOSTAT HEAT ANTICIPATOR SETTING:VR4200: 0.1AVR8200: 0.5ATYPE OF GAS: VR8200 and VR4200 set up for naturalgas includes a 393691 LP Conversion Kit. See Figs. Your system is quite old and somewhat unsafe, in that the pilot comes off ahead of the safety valve. Refer to Figs. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION. 0000016083 00000 n Safety shutoff or pilot gas proves complete shutdown since the safety shutoff valve permits main burner and pilot gas flow. Paint all pipe connections upstream of the gas control with a rich soap and water solution. CHECK SAFETY SHUTDOWN PERFORMANCEWARNING!FIRE OR EXPLOSION HAZARDS CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH.Perform the safety shutdown test any time work is done on a gas system. 0000003485 00000 n The electrical/scientific basis for millivolt systems is the Seebeck . This makes it ideal for fireplace and space heating uses that are vent free. Mount gas control high enough above cabinet bottom to avoid exposure to flooding or splashing water. These controls combine a manual gas cock, automatic pilot safety valve and a millivolt operator. TO LIGHT THE PILOT BURNERSTOP! When the thermostat calls for heat, the first automatic valve and the second automatic valve operator open. EASY FIXES! <<50A7D4D2F74D8141B7F3BE8FD5737B51>]/Prev 36635>> Home and Building ControlHoneywell Inc.1985 Douglas Drive NorthGolden Valley, Minnesota 55422, Home and Building ControlHoneywell LimitedHoneywell Limite740 Ellesmere RoadScarborough, OntarioM1P 2V9, This is a legacy product document supported by Resideo. I was trying to use the "MILLIVOLT TROUBLESHOOTING CHART", on page 2 of this . To ensure proper operation, follow these guidelines: Locate the gas control in the appliance vestibule on the gas manifold. In the "Resources for understanding gas valves" thread in the HVAC forum, someone wanted to know how a gas valve worked. 0000026455 00000 n Flanges available for 3/8, 1/2 and 3/4 inch straight and 90 angle connection. Then tighten one more turn with a wrench. To adjust the pilot flame: LIGHT MAIN BURNERFollow the appliance manufacturer instructions or set the thermostat setting above room temperature to call for heat. Install ThermocoupleThe Q340A Thermocouple (with adapters) is provided with SUPER TRADELINE models of the VR8200A. Do not force the gas control knob. With the . I was just wondering about this the other day. 0000008225 00000 n Zero clearance sleeve is only required for combustible walls. Vermont Castings, Majestic Products: DVR33, Window Frame Assembly Should be Removed Before Service Work, Troubleshooting Honeywell Millivolt Valve, Homeowner's Installation and Operating Manual. Residential and Building Controls Division Customer Satisfaction. The second automatic valve diaphragm, controlled by the servo pressure regulator, opens and adjusts gas flow as long as the system is powered and the pilot is burning. Below are my tests: SIT 822 Valve with a Honeywell Electronic Igniter NOTE: Remove glass before servicing. Several troubleshooting methods applied to and including bypassing the thermostat but failed to yield any results. Use conversion factors in Table 2 to convert to capacities for other gases. If it fires, it is working correctly. Good reading is 0 to 0.2 Ohms . Otherwise, take the necessary steps to provide proper gas pressure to the gas control. TABLE 7PRESSURE REGULATOR SPECIFICATION PRESSURES IN INCHES WC. POWER SUPPLY. This increases gas pressure under the automatic valve and repositions the valve disc closer to the seat. Order number, SUPER TRADELINE or TRADELINE if desired. Intermittent use. In this HVAC Furnace Video, I go over the Operation and Troubleshooting of a 750 Millivolt Gas Valve and Thermopile/PowerPile. Run pipe or tubing to the gas control. The servo pressure regulator monitors outlet pressure to provide n even the main burner gas flow. The diaphragm-operated second automatic valve opens under the control of the regulator and closes if gas or power supply is interrupted. 6. to protect them and prevent gas from leaking, and discourage tampering by untrained people. Apply a moderate amount of good quality pipe compound to bushing, leaving two end threads bare. 0000013062 00000 n 4. Did this satellite streak past the Hubble Space Telescope so close that it was out of focus? hW[o8+ID:BZ(gENRCD'$( m;\{fgc3llFQl%|xI!>-88zzhb|AtJOr[b4-BFS! It is no longer manufactured Pressure Switch Installation Addendum, Gas Detection Quick Reference GuideHoneywell BW Solo Portable Single gas Detector 2020, Oct 23 G05-4001-000-RevC Overview Contact, RYOBI RY802925 PSI Gas Pressure Washer WARNING: This Quick Reference Guide is not a substitute for reading the, KitchenAid Gas Range User Manual - Optimized PDF KitchenAid Gas Range User Manual - Original PDF, Your email address will not be published. 0000006141 00000 n TRADELINE model specifications are the same as those of standard models except as noted below.TRADELINE MODEL AVAILABLE: VR8200A Continuous Pilot Dual Automatic Combination Gas Control. 1. By clicking Post Your Answer, you agree to our terms of service, privacy policy and cookie policy. Follow these warnings exactly: CAUTIONNever apply a jumper across or short the valve coil terminals. Please comment and ask for videos that you would like to see in the future! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from any purchases after clicking through. It looks like you're using an ad blocker. 0000004941 00000 n See Fig. Insert the replacement spring with the tapered end down. When the thermostat calls for heat, the automatic operator valve disc opens. Set the thermostat to the lowest setting and shut off the electric power to the appliance. With the loss of outlet pressure, the second automatic valve closes and is held closed by spring pressure on the diaphragm. A stuck valve could release gas into the air without regulation or the valve could cause the unit not to fire up at all. Where the cost of an unexpected shutdown would be high, the system should be checked more ften. We get it, but (1) terrylove.com can't live without ads, and (2) ad blockers can cause issues with videos and comments. The automatic pilot safety is separate from the gas cock and provides gas shut Off in case of pilot Outage. CONVERTING BETWEEN NATURAL AND LP GAS WARNING!FIRE OR EXPLOSION HAZARDS CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH. Troubleshooting the valve and looking for known common issues will give you peace of mind by ensuring the safe operation of your Honeywell appliance. Check the ratings given in the instructions and on the product to ensure the product is suitable for your application. Thanks. The gas control must be manually reset. Release button; the pilot should remain lit. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. The pilot will remain lit, ready for return to normal service without relighting.COMPLETE SHUTDOWN: Turn the gas control knob clockwise to OFF. If your gas supplier cannot be reached, call the fire department. Attempted disassembly or repair may damage the gas control. Carefully check the main burner light off at the step pressure. Remove the thermopile wiring connector from the gas control. If pilot burner flame still goes out, measure the open and closed thermocouple output voltage. If you then smell gas in the appliance area or near the floor in an LP installation, immediately shut off the manual valve in the gas piping to the appliance or, with LP, shut off at the tank. While taking a Millivolt reading on a safety magnet, disconnect thermocouple & wires from the valve. millivoltage automatic valve operator, and optional gas pressure regulator. If you smell gas, immediately shut off the manual valve in the gas piping to the appliance or, on LP, at the tank. This is How to Wire the Thermopile to The 750mv Gas Valve for the Pilot and Main Gas Burners. 0000098789 00000 n The gas control should e replaced if: It does not perform properly on checkout or troubleshooting. If the pilot flame has gone out, follow these instructions exactly: TO TURN OFF THE APPLIANCEVACATION SHUTDOWN: Turn gas control knob clockwise from ON to PILOT. 0000015409 00000 n Two convenience terminals on top of control(optional). wc [0.9 kPa] outlet pressure). View our resources. For push-in clip-type pilot burners: From beneath, insert the tip of the Q340 into the hole or barrel of the pilot burner. (50/60 Hz models available on request. Before lighting, smell all around the appliance area for gas. Check the power supply rating on the valve and make sure it matches the available supply. 10 0 obj <> endobj I am trying to diagnose a problem with an old furnace. The condition of the wiring is also suspect; loose connections, old oxidized control contacts, an old thermostat, are all potential problems. VR8200J has a six-second delay from when the thermostat calls for heat until the main gas valve opens. Find many great new & used options and get the best deals for Robertshaw 710-502 Millivolt Low Capacity Gas Valve, 1/2" x 1/2", 70,000 BTU at the best online prices at eBay! The gas valve cannot be repaired in the field. . Locate the hot surface igniter and look for a spark or glow there. If the desired outlet gas pressure or gas flow rate cannot be achieved by adjusting the gas control, check the gas control inlet pressure using a manometer at the inlet pressure tap. The reduced pressure on the bottom of the automatic valve diaphragm repositions the diaphragm downward away from the valve seat, allowing main burner gas flow. All adjustments, wiring connections, and pilot outlets are accessible from the top of the gas control. Do I need a thermal expansion tank if I already have a pressure tank? Capacity is based on 1000 Btu/feet 3, 0.64 specific gravity natural gas at 1-inch water column pressure drop [37.3 MJ/meters 3, 0.64 specific gravity natural gas at 0.25 kPa pressure drop].The maximum regulated capacity is 200 feet 3 /hour [5.7 meters 3 /hour]. Install thermostat, and other controls as required. If any particular ad is your REASON for blocking ads, please let us know. There must be two terminals in this connector block that powers the gas valve coil. 0000003373 00000 n The gas control knob must be held depressed or the thermocouple must be heated sufficiently to hold the safety control valve open.ON: Permits main burner and pilot gas flow. )POWER UNIT:Hold-in current: 300 mA maximum.Drop-out current: 250 to 90 mA.THERMOCOUPLE:Nominal output: 30 mV (0.018 ohms).Open Circuit Turndown Voltage: 2 mV.ELECTRICAL CONNECTIONS (2): 1/4 inch male quick-connects. DO NOT JUMPER THESE TERMINALS. I would not work on it, without completely replaceing the gas control system, and the furnace may not be worth that expense. . 244 0 obj << /Linearized 1 /O 247 /H [ 2388 392 ] /L 541180 /E 139793 /N 4 /T 536181 >> endobj xref 244 91 0000000016 00000 n TABLE 5MAXIMUM LENGTH OF SUPPLEMENTARY LIMIT LEAD WIRES WHEN USING Q340A THERMOCOUPLE. If the knob or reset button will not operate by hand, replace the control using a qualified service technician. JavaScript is disabled. 0000057737 00000 n Refer to Fig. 4 0 obj <> endobj 0000001377 00000 n Avoid locating gas control where exposure to corrosive chemical fumes or dripping water are likely. One Q340A 36-inch thermocouple with adapters and clip. 0000044905 00000 n 0000023590 00000 n Do not bend pilot tubing at gas control or pilot burner after compression fitting has been tightened, or gas leakage at the connection may result. Hunker may earn compensation through affiliate links in this story. Capacity rated at 130 feet 3 /hour at 1-inch WC pressure drop [3.7 m 3 /hr at 0.25 kPa]. Gas valves are not serviceable; the following are simple troubleshooting and description of how gas valves operate. Tighten only 1/4 turn beyond finger tight to give good electrical continuity. The low-pressureregulator maintains outlet pressure at the preset step rate for several seconds. Compare it to the acceptable range charts in the thermocouple specifications or in the Gas Controls Handbook. 0000043015 00000 n When you purchase through links on our site, we may earn an affiliate commission, which supports our community. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: BODY PATTERN: Straight-through with 1/2 inch inlet and 1/2 inch outlet. WHEN THE THERMOSTAT CALLS FOR HEATThe gas control allows pilot and main burner gas flow during the thermostat ON cycle, as shown in Fig. inlet and 1/2 inch outlet; adapters available for 3/8 or 3/4 inch. The main burner should go off and the pilot should remain lit. 0000005594 00000 n You should NOT short out the t'stat terminals to check it. Never use any tools. Refer to Fig. 10 Easy Things to Check When Troubleshooting a Furnace Gas Valve. For screen reader problems with this website, please call 1-800-430 . To learn more, see our tips on writing great answers. 30 0 obj <>/Filter/FlateDecode/ID[<07B8336975034BD12756FE90D2FD37D3>]/Index[10 37]/Info 9 0 R/Length 96/Prev 25390/Root 11 0 R/Size 47/Type/XRef/W[1 2 1]>>stream Mount the gas control 0-90 degrees, in any direction, from the upright position of the gas control knob, including vertically. Both pilot and main burner are shut off. Since these environments can cause the gas control to deteriorate more rapidly, the system should e checked more often. Install Piping to Gas ControlAll piping must comply with local codes and ordinances or with the National Fuel Gas Code (ANSI Z223.1 NFPA No. Check the regulator setting either with a manometer or by clocking the gas meter. Do NOT use Teflon tape. The gas control is likely to have operated for more than 200,000 cycles. It does so for the very first instance both in the morning and night but thereafter, the pilot just stays lit and the chambers aren't lit or heating the house. Bashing my head against the walls in some of the internet's finest chat rooms. Stand clear while lighting the main burner to prevent injury caused by hidden gas leaks, which could cause flashbacks in the appliance vestibule. CONVENIENCE TERMINALS SERVE AS A TIE POINT ONLY. After the adapter is installed, the gas control is attached to the adapter as outlined above. If it then "clicks" meaning it is opening with voltage supplied to it than most likely it's not the gas valve which is bad. 4 41 Troubleshooting an IID control system calls for an AC voltmeter with a 220-volt range or greater. 0000004689 00000 n Light the main burner. 0000002189 00000 n If the reset button does not pop up when released, stop immediately and call your service technician or gas supplier. Assure the main burner primary air supply is properly adjusted for complete combustion (refer to the appliance manufacturer instructions). Gas control operation is described in more detail below.VALVE POSITION DURING THERMOSTAT OFFCYCLEThe valve is positioned as shown in Fig. 0000015431 00000 n Do not overtighten. Therefore, this unit may not exactly match the listed specifications. WHEN THE CALL FOR HEAT ENDSWhen the call for heat ends, the first automatic valve and the second automatic valve operator close, bypassing the regulator(s) and hutting ff the main burner. Honeywell Gas Valve Code 5 Whirlpool Water Heater Flammable Vapor Sensor Lockout How To Reset Honeywell Water Heater Pilot Keeps Going out - CLEAN THE FILTER GRATE! 0000036895 00000 n You must log in or register to reply here. See Fig. IMPORTANT: These gas controls are shipped with protective seals over inlet and outlet tappings. 400 millivolts across the generator loadedcurrent flowing through the switches and valvesis about right. rating 1/2 psi [3.5 kPa] inlet pressure.PRESSURE REGULATION: See Table 1. Is it correct to use "the" before "materials used in making buildings are"? Connect the pipe to gas control inlet and outlet. (supposedly so they could fix them :yes: ), Cool. When the pilot remains lit, turn the gas control knob counterclockwise. Do not remove the existing window frame assembly. If you have problems accessing your account, please contact us at 1-888-757-4774 and we'll help you out. Because gas is involved, problems with gas valves are a major safety concern. Troubleshooting Honeywell Millivolt Valve, Troubleshooting the Gas Control System, Troubleshooting the Gas Control System, Vermont Castings, Majestic Products: DVR33, SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Rear V ented Direct V ent Gas Fireplace Model: PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE. The condition of the wiring is also suspect; loose connections, old oxidized control contacts, an old thermostat, are all potential problems. Mutually exclusive execution using std::atomic? 00. Readjust the full rate outlet pressure if necessary to improve light off characteristics. 0000034510 00000 n hb``b``r` LT, bBPQ%@AL;LiaP2l3 2 The boiler comes on twice a day - morning and night. Standard Opening Pressure Regulation (VR8200A,M, and VR4200A, M)During the ON cycle, the servo pressure regulator provides close control of outlet pressure, even if inlet pressure and flow rate vary widely. Test the voltage using an AC voltmeter. The internal valve coil must then be connected to the topmost and bottommost of the four terminals. Is there a solution to add special characters from software and how to do it. http://www.robertshawtstats.com/spaw2/SiteContent/Files/faq/ControlTips-MillivoltSystems.pdf, http://en.wikipedia.org/wiki/American_wire_gauge, http://americanhvacparts.com/Merchantegory_Code=GV, http://americanhvacparts.com/Merchant2/merchant.mvc?Screen=PROD&Product_Code=GSV820A1047A&Category_Code=GV, http://en.wikipedia.org/wiki/Node_(circuits, http://www.emersonclimate.com/en-US/products/valves/Documents/0037-6264.pdf. With the main burner in operation, paint all pipe joints (including adapters) and gas control inlet and outlet with rich soap and water solution. Tubing installation must comply with approved standards and practices. If resistance is outside of specifications listed, the gas valve must be replaced. Never use any tools. They require the use of a 750 mv Powerpile generator (thermopile). PERFORM GAS LEAK TEST WARNING!FIRE OR EXPLOSION HAZARDS CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH.Check for gas leaks with rich soap and water solution any time work is done on a gas control. If: Measure the open and closed thermocouple output voltages and compare to the acceptable range charts in the thermocouple specifications or in the Gas Controls Handbook. Hold down the gas control knob about one minute, then release. If desired outlet pressure or flow rate cannot be achieved by adjusting the gas control, check the inlet pressure using a manometer at the inlet pressure tap or upstream of the gas control. So in short, I get heat both times of the day for say an hour and it just sits idle with the pilot lit. Stack Exchange network consists of 181 Q&A communities including Stack Overflow, the largest, most trusted online community for developers to learn, share their knowledge, and build their careers. 0000019943 00000 n 0000004324 00000 n Install the Q340A asfollows: Connect ThermocoupleConnect thermocouple lead as shown in Fig. If something is wrong with the internal components of the gas valve, the gas valve should be replaced. You may have to wiggle it a bit before it comes loose. See Accessories.CAPACITY: 130 feet 3 /hour [4.2 meters 3 /hour]. Turn the inner adjustment screw clockwise. To avoid the dangerous accumulation of fuel gas, turn off the gas supply at the appliance service valve before starting the installation, and perform Gas Leak Test after completion of installation. When installing the appliance as a rear vent unit, the 90. mention that I got the main burner to light on 2 occassions by tapping on either the gas pipe before the main shutoff valve, or on the honeywell gas millivolt valve itself. Use new, properly reamed pipe free from chips. Straight-through body pattern; right-angle adapters available for inlet and outlet. Determine if the pilot burner requires a thermocouple with a push-in clip or attachment nut, and attach the correct adapter to the. 0000055306 00000 n For use in standing pilot appliances. Do not bend tubing at gas control or pilot burner after compression fitting has been tightened, as this may result in a gas leakage at the connection. 0000034533 00000 n Filter. thatguy, I hear you. LP to natural gas conversion kit available for standard and slow-opening models. Regulator Cap Conversion Screw Pressure Regulator Housing, Cleaning the Standing Pilot Control System. 0000013008 00000 n Loss of power closes the automatic valves, but leaves the pilot lit, ready to return to normal service when power is restored. A contractor came by and gave it a crack at it and said it was the gas valve but I'm not confident that that could be the problem as from reading this post, the thermoCOUPLE should be swapped out first before assuming it is the gas valve as it is a more pricey unit to replace. By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. A place where magic is studied and practiced? trailer ECO connector included with some models: also available as an accessory. Apply a moderate amount of good quality pipe compound (Do not use Teflon tape) to pipe only, leaving two end threads bare. But it has been reliable for a long time. Lv 4. Turn the gas control knob to the "On" position if the main burner does not turn on when the thermostat or controller is adjusted to start the appliance.